Table

4-1

(Page 6 of

11).

Firmware Error Codes

 

 

 

 

 

 

Error

Code

 

Function

/

 

 

 

 

Repair

Action/Possible Failing

FRU

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25010000

 

No diskette in

driveInsert diskette containing firmware update file

 

 

 

 

 

 

 

 

 

 

 

25010001

 

Diskette

seek

error 1. Retry function.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Replace

diskette

drive

 

 

 

 

 

 

 

 

 

 

 

 

3. Replace

diskette

cable

 

 

 

 

 

 

 

 

 

 

 

 

4. Replace

System

Planar

 

 

 

 

 

 

 

 

 

25010002

 

Diskette in drive Insert diskette with

firmware update file

 

 

 

does

not

contain

 

an

 

 

 

 

 

 

 

 

 

 

 

 

 

*.IMG

file

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25010003

 

Cannot

open

 

 

 

 

1. Replace

System

Planar

 

 

 

 

 

 

OPENPROM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

package

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25010004

 

Cannot

find

 

 

 

 

1. Replace

System

Planar

 

 

 

 

 

 

OPENPROM

node

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25010006

 

System

id

does

notMake

sure

correct

firmware update diskette is being

 

 

 

match

image

system used

with

 

this

system.

 

 

 

 

 

 

id

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25010007

 

Image

has

bad

 

CRC

1. Replace

firmware

updated

diskette

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25010008

 

Flash

is

write

 

 

 

1. Power

Off/On

machine

and

retry

 

 

 

protected,

update

2. Replace

System

Planar

 

 

 

 

 

 

cancelled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25010009

 

Flash

module

is

 

 

Make sure correct firmware update diskette is being

 

 

 

unsupported or not used with this system.

 

 

 

 

 

 

recognized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2501000A

 

Flash

write

 

 

 

 

1. Power

Off/On

machine

and

retry

 

 

 

protected.

 

 

 

 

2. Replace

System

Planar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NVRAM

problems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NVRAM problem resolution:

1.Errors reported against NVRAM can be caused by low Battery voltage and (more rarely) power outages that occur during normal system usage. With the exception of the 25A80000 error, these errors are really just warnings that the NVRAM data content had to be re-established and do not

require

any

FRU replacement

unless

the error is persistent. When one of these errors occurs,

any

system

customization (eg.

boot

device list) information has been lost, the system may need

to

be

re-configured.

 

 

2. If the error is persistent, replace the battery.

3. If

the error

is

persistent

after

battery

replacement, or

the error code is 25A80000, replace the

System

Planar.

 

 

 

 

 

 

 

 

 

 

 

 

 

25A80000

 

Initialization

failed,Refer to NVRAM problem resolution above

 

 

device

test failed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25A80001

 

init-nvram

invoked,

Refer

to NVRAM

problem resolution

above

 

 

ALL

of

NVRAM

 

 

 

 

 

 

 

initialized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-67043 43P Series Service Guide

Page 118
Image 118
IBM SA38-0512-03 manual Img, Nvram problem resolution