IBM SA38-0512-03 manual NOGo to B-15 on YES Go to B-16 on

Models: SA38-0512-03

1 253
Download 253 pages 34.64 Kb
Page 87
Image 87

Step 1540B-13

Look at the FRU part numbers associated with the SRN.

Have you exchanged all the FRUs that correspond to the failing function codes?

NOExchange the FRU with the highest failure percentage that has not been changed.

Repeat this step until all the FRUs associated with the SRN have been exchanged or diagnostics run with no trouble found. Run diagnostics after each FRU is exchanged.

 

If

the

system

board or

a network

adapter is replaced, see notes on p

 

2-1.

 

 

 

 

 

 

 

Go to "Map 0410: Repair Checkout"Diagnosticsin the Information for

 

Multiple Bus Systems.

 

 

 

YES

If

the

symptom

did not

change

and

all the FRUs have been exchanged,

 

call

your

service support

person

for

assistance.

Step 1540B-14

Does the system have adapters or devices that require supplemental media?

NOGo to “Step 1540B-15” on page 2-52.

YES Go to “Step 1540B-16” on page 2-52.

Chapter 2. Maintenance Analysis Procedures 2-51(MAPs)

Page 87
Image 87
IBM SA38-0512-03 manual NOGo to B-15 on YES Go to B-16 on