Step
1. Make sure the diagnostic
2. Turn the power off.
3. Plug the SCSI cable into the SCSI connector on the system board.
4. Disconnect | the signal and power connectors from all the SCSI devices except |
the | drive. |
5.Make sure that the SCSI chain is still properly terminated; see “SCSI Bus Termination” on page
6.Turn the power on.
7.After the keyboard indicator is displayed, press the F5 key on the
8. Enter the appropriate password when prompted to do so.
Is the "Please define the System Console" screen displayed?
NOOne of the FRUs remaining in the system unit is defective.
In the following order, exchange the FRUs that have not been exchanged:
1. SCSI cable termination (see “SCSI Bus Termination” on page
2. SCSI cable
3. Last SCSI device connected
4.The graphics adapter, if the system console is defined as a graphi display.
5.The riser card.
6. System board (See notes on page
7. Power Supply
Repeat this | step | until the defective FRU is | identified | or | all | the FRU | |||||||||
been | exchanged. |
|
|
|
|
|
|
|
|
|
|
|
| ||
If | the | symptom did not change and | all the FRUs have been | exchanged, | |||||||||||
call | your | service support person for assistance. |
|
|
|
| |||||||||
If | the | symptom has | changed, | check | for | loose | cards, | cables, | and | obvious | |||||
problems. | If | you | do | not | find | a | problem, | return to “Step | on | ||||||
page | in | this MAP | and | follow | the | instructions | for | the | new | symptom. | |||||
|
|
|
| Chapter 2. Maintenance | Analysis | Procedures |
|
|
|