Example: 000.000.000.000

Table

3-2

(Page 2 of 9).

Firmware Error Codes.

 

 

Error

Code

Description

Action/

 

 

 

Possible Failing FRU

 

 

 

 

 

003

Power on Password must be set forUnattended mode requires the setting

 

 

Unattended mode

of

the Power On password before can

 

 

 

be

enabled.

004Battery drained or needs replacement1. Replace battery.

2.Replace system board. (See notes on page 3-1.)

005

EEPROM

locked

 

 

1. Turn

off,

then

turn

on system

unit.

 

 

 

 

 

 

 

2. Replace

the

system

board. (See

 

 

 

 

 

 

 

notes

on

page

3-1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

008

CMOS

 

corrupted or

tampering

evident,Check

your

machine

for

evidence

of

 

CMOS

 

initialized

 

tampering.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If

no

tampering

evident:

 

 

 

 

 

 

 

 

 

 

 

 

1. Replace

battery, restore NVRAM

 

 

 

 

 

 

 

 

data

(passwords,

startup

data)

 

 

 

 

 

 

 

 

2. Replace

system

board. (See

notes

 

 

 

 

 

 

 

on

page

3-1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

009

Invalid password entered - systemThe password

has

been

entered

 

 

 

locked

 

 

 

incorrectly

3

times.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn

off, then turn

on

the

system

unit,

 

 

 

 

 

 

 

then

enter

the

password

correctly.

 

 

 

 

 

 

 

 

 

 

 

 

00A

EEPROM

lock

problem

 

If

for

priviliged-access

password

install,

 

 

 

 

 

 

 

is jumper in correct position?

 

 

 

 

 

 

 

 

 

Consult the system's User's Guide for

 

 

 

 

 

 

 

jumper location

and

position.

 

 

 

 

 

 

 

 

 

 

 

1. Turn

off,

turn

on

system

unit.

 

 

 

 

 

 

 

 

2. Replace

system

board. (See

notes

 

 

 

 

 

 

 

on page 3-1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00B

EEPROM

write

problem

1. Turn

off,

turn

on

system

unit.

 

 

 

 

 

 

 

 

2. Replace

system

board. (See

notes

 

 

 

 

 

 

 

on

page

3-1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00C

EEPROM

read

problem

1. Turn

off,

turn

on

system

unit.

 

 

 

 

 

 

 

 

2. Replace

system

board. (See

notes

 

 

 

 

 

 

 

on page 3-1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

017

Cold boot needed for password Turnentryoff, turn

on

 

system

unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20EE0xxx

Informational

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

xxx=003

SMS:

Invalid

RIPL

IP address (requiresEntervalid

RIPL

IP

address.

 

 

 

3

dots

".")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chapter 3. Error Code to FRU Index for Model 1403-5and Model 240

Page 95
Image 95
IBM SA38-0512-03 manual Code Description Action Possible Failing FRU