Step
One | of | the | FRUs | remaining | in | the | system | unit | is | defective. |
|
|
| ||||||||
1. Turn | the | power | off. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
2. Exchange | the following FRUs the order listed. |
|
|
|
| ||||||||||||||||
| a. System | board | (See | notes | on | page |
|
|
|
|
|
| |||||||||
| b. Power supply |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
3. Turn | the | power | on. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Does | the | operator | panel | stabilize | for | more | than | 60 | seconds with | code | FDC, |
|
|
|
| ||||||
FF2, | FF3, | or | F4D | displayed, | or is | one | of these codes displayed immediately |
|
|
|
| ||||||||||
before | the | system | unit | attempts | to | restart? |
|
|
|
|
|
|
|
|
| ||||||
NO |
| Reinstall | the | original | FRU. |
|
|
|
|
|
|
|
|
| |||||||
|
| Repeat | this | step | until | the | defective FRU is | identified | or | all the FRU | |||||||||||
|
| been | exchanged. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| If | the | symptom | did | not change and all the FRUs have been | exchanged, | ||||||||||||||
|
| call | your | service | support | person | for | assistance. |
|
|
| ||||||||||
|
| If | the | symptom | has | changed, | check for | loose cards, cables, and obvious | |||||||||||||
|
| problems. | If | you | do | not | find a | problem, | return to “Step | ||||||||||||
|
| page | in |
| this | MAP, | and | follow | the | instructions | for | the | new | symptom. | |||||||
YES |
| Go | to | "Map | 0410: | Repair | Checkout"Diagnosticsin the | Information | for |
|
| ||||||||||
|
| Multiple | Bus | Systems. |
|
|
|
|
|
|
|
|
|
|
|
Chapter 2. Maintenance Analysis Procedures