Step 1540A-3

One of the FRUs remaining in the system unit is defective.

1. Turn the power off.

2. Exchange one of the FRUs in the following list.

 

a. System

board

(See

notes on

2-1.)

 

 

b. Riser card

 

 

 

 

 

 

 

c. Memory module

 

 

 

 

 

3. Turn

the

power

on.

 

 

 

Does

the

operator

panel

do

one

of

the

following:

 

Ÿ

Stop

with

any

code

other

than

 

 

 

 

FDC,

FF2,

FF3,

or

F4D

(Model

140)

 

 

E1DC,

E1F2,

E1F3,

E1F7,

or E14D

(Model 150)

ŸAlternate between

FFD

and

any

other

code (Model

140)

 

 

 

 

 

 

 

E1FD

and

any

 

other

code

(Model

150)

 

 

 

 

 

 

 

NO

Go

to

"Map

0410:

Repair

Checkout"Diagnosticsin the

Information

for

 

 

 

Multiple

 

Bus Systems.

 

 

 

 

 

 

 

 

 

YES

Reinstall

the

original

FRU.

 

 

 

 

 

 

 

Repeat

 

the FRU replacement steps until

the defective

FRU

is identified or

 

all

the

 

FRUs

have

been

exchanged.

 

 

 

 

 

 

If

the

symptom

did

not

change

and

all

the FRUs have been exchanged,

 

call

your

service

support

person

for

assistance.

 

 

 

 

If

the

symptom has changed, check for loose cards, cables, and obvious

 

problems. If you do not

find a

problem,

return to “Step 1540A-1” on

 

page 2-22

in

this

MAP

and

follow

the

instructions for

the

new

symptom.

2-247043 43P Series Service Guide