![](/images/new-backgrounds/1196490/196490107x1.webp)
Step 1520-4
Note: Either the power supply, the system board, or the power switch is defective.
To test each FRU, exchange the FRUs that have not already been exchanged in the following order.
ŸPower supply
ŸPower Switch
ŸSystem board (See notes on
2. | Unplug | the | system | unit | power | cable | from | the | wall | outlet. | ||||||
3. | Exchange | one | of | the | FRUs | in | the | list. |
|
|
| |||||
4. | Connect | the | system | unit | power | cable | to | the | wall | outlet. | ||||||
5. Turn | the | power on. |
|
|
|
|
|
|
|
|
|
| ||||
Does | the | fan | in | the | power | supply | turn | on and | the | power LED | come | on and | stay | |||
on? |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOReinstall the original FRU.
Repeat this step until the defective FRU is identified.
YES Go to "Map 0410: Repair Checkout"Diagnosticsin the Information for
Multiple Bus Systems.