Step 1540B-3

One of the FRUs remaining in the system unit is defective.

If the following steps call for a system board to be replaced, see notes on

1.If the disk LED is on, turn the power off and exchange the following FRUs order:

a.Memory modules (pair)

b. Riser card

c. System board (See notes on page 2-1)

2.If the disk LED is off, turn the power off and exchange the following FRUs order:

a.Processor cards

b. Memory modules (pair)

c. Riser card

d. System board (See notes on page 2-1)

Does

the

operator

 

panel

stabilize

for

more

than

60

seconds

with code

FDC,

 

 

 

FF2,

FF3,

or F4D

displayed,

 

or is

one

of these codes displayed immediately

 

 

 

before

the

system

unit

attempts

to

restart?

 

 

 

 

 

 

 

 

 

NO

 

Reinstall

the

original

FRU.

 

 

 

 

 

 

 

 

 

 

Repeat

the

 

FRU

replacement

steps

until

the defective

FRU

is identified

 

 

all

the

FRUs

have

been

exchanged.

 

 

 

 

 

 

 

If

 

the

symptom

did

not change and all the FRUs have been exchanged,

 

 

call

 

your

service support person for assistance.

 

 

 

 

 

If

 

the

symptom

has

changed,

check

for

loose cards, cables, and obvious

 

 

problems.

If

 

you

do

not

find

a

problem,

return to “Step 1540B-1” on

 

 

page 2-39

in

 

this

MAP

and

follow

the

instructions for

the

new

symptom.

YES

 

Go

to

"Map

0410:

Repair

Checkout"Diagnosticsin the

Information

for

 

 

 

 

Multiple

Bus

Systems.

 

 

 

 

 

 

 

 

 

 

 

Chapter 2. Maintenance Analysis Procedures 2-41(MAPs)

Page 77
Image 77