YES | If | there | is | only | one | memory | module | installed, go to | “Step | |
| page |
|
|
|
|
|
|
|
| |
| If | there | is | more | than | one | memory | module installed, | go to | “Step |
Step 1240-2
1. Power off the system. Refer to "Powering Off the System".
2.Remove all but one of the installed memory modules. Record the position of th memory modules removed so that when instructed to
3. Power on the system. Refer to "Powering On the System".
Does the system stop with a memory checkpoint displayed on the operator panel?
NORepeat this step until all the memory modules have been installed and tested.
If all the memory modules have been installed, reseating the memory modules has corrected the problem.
Go to"MAP 0410: Repair Checkout" in theDiagnostics Information for
Multiple Bus Systems.
YES Go to “Step
Step 1240-3
The | failure may be caused by | the | last memory module installed or the system b |
To | isolate the failing FRU do | the | following: |
1. Power off the system. Refer to "Powering Off the System".
2. Exchange the last memory module installed.
3. Power on the system. Refer to "Powering On the System".
Does the | system stop with | a memory | checkpoint displayed on the operator | |||
panel? |
|
|
|
|
|
|
NO | Go | to"MAP | 0410: | Repair Checkout" in theDiagnostics Information for | ||
| Multiple | Bus | Systems. |
| ||
YES | Go | to | “Step |
| on page |
Chapter 2. Maintenance Analysis Procedures