YES

If

there

is

only

one

memory

module

installed, go to

“Step

1240-3” on

 

page

2-13.

 

 

 

 

 

 

 

 

 

If

there

is

more

than

one

memory

module installed,

go to

“Step 1240-2.”

Step 1240-2

1. Power off the system. Refer to "Powering Off the System".

2.Remove all but one of the installed memory modules. Record the position of th memory modules removed so that when instructed to re-install them, they can be installed in their original positions.

3. Power on the system. Refer to "Powering On the System".

Does the system stop with a memory checkpoint displayed on the operator panel?

NORepeat this step until all the memory modules have been installed and tested.

If all the memory modules have been installed, reseating the memory modules has corrected the problem.

Go to"MAP 0410: Repair Checkout" in theDiagnostics Information for

Multiple Bus Systems.

YES Go to “Step 1240-3.”

Step 1240-3

The

failure may be caused by

the

last memory module installed or the system b

To

isolate the failing FRU do

the

following:

1. Power off the system. Refer to "Powering Off the System".

2. Exchange the last memory module installed.

3. Power on the system. Refer to "Powering On the System".

Does the

system stop with

a memory

checkpoint displayed on the operator

panel?

 

 

 

 

 

 

NO

Go

to"MAP

0410:

Repair Checkout" in theDiagnostics Information for

 

Multiple

Bus

Systems.

 

YES

Go

to

“Step

 

1240-4”

on page 2-14.

Chapter 2. Maintenance Analysis Procedures 2-13(MAPs)

Page 49