Table

3-2

(Page

5

of

9).

Firmware Error Codes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error

Code

 

Description

 

 

 

Action/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Possible

Failing

FRU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00A

 

Flash

write

protected.

1. Turn

off,

turn

on

system

unit,

retry.

 

 

 

 

 

 

 

 

2. Replace

system

board. (See

notes

 

 

 

 

 

 

 

 

on page 3-1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25A0xxy0

 

Cache:

L2

controller failure

Refer

to

error code 2B2xxyrr for a

 

 

 

 

 

 

 

 

description

of

the

“xx”

and

 

“y”

values.

 

 

 

 

 

 

 

 

For

Model

140:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. L2 Cache

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. System

board

(See

notes

on

page

 

 

 

 

 

 

 

 

3-1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For

Model

240:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Processor card

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. System

board

(See

notes

on

page

 

 

 

 

 

 

 

 

3-1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25A1xxy0

 

Cache:

L2

SRAM

failure

Refer

to

Error code 2B2xxyrr for a

 

 

 

 

 

 

 

 

description

of

the

“xx”

and

 

“y”

values.

 

 

 

 

 

 

 

 

For

Model

140:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. L2 Cache

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. System

board

(See

notes

on

page

 

 

 

 

 

 

 

 

3-1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For

Model

240:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Processor card

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. System

board

(See

notes

on

page

 

 

 

 

 

 

 

 

3-1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25A80xxx

 

NVRAM

 

 

 

 

Note:

 

Errors

reported

against

NVRAM

 

 

 

 

 

 

 

 

 

can

be

caused by

low Battery

voltage

 

 

 

 

 

 

 

 

and (more rarely) power outages that

 

 

 

 

 

 

 

 

occur during normal system usage.

 

 

 

 

 

 

 

 

 

With the exception of the 25A80000

 

 

 

 

 

 

 

 

 

error,

these

errors

are

warnings

that

 

 

 

 

 

 

 

 

the

 

NVRAM

data

content

had to be

 

 

 

 

 

 

 

 

 

re-established and do not require

any

 

 

 

 

 

 

 

 

FRU replacement unless the error is

 

 

 

 

 

 

 

 

persistent. When one of these errors

 

 

 

 

 

 

 

 

occurs, any system customization (eg.

 

 

 

 

 

 

 

 

boot

 

device

list)

information

has

been

 

 

 

 

 

 

 

 

lost, the system may need to be

 

 

 

 

 

 

 

 

 

reconfigured.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the error is persistent, replace the

 

 

 

 

 

 

 

 

battery.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the error is persistent after battery

 

 

 

 

 

 

 

 

replacement, or the error code is

 

 

 

 

 

 

 

 

25A80000, replace the system board.

 

 

 

 

 

 

 

 

 

(See

notes

on

page

3-1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-87043 43P Series Service Guide

Page 98
Image 98
IBM SA38-0512-03 manual Errors Reported Against