7. Check for alterations or attachments. If there are any, check for obvious safety hazards such as broken wires, sharp edges, or broken insulation.

8. Check the internal cables for damage.

9. Check for dirt, water, and any other contamination within the system unit.

10. Check the voltage switch

on

the back of

the

system unit to ensure that it

matches the voltage at

the

outlet (Model

140

and M240. only.)

11. Check the external power cable for damage.

12. With the

external power cable

connected

to

the

system unit, check for 0.1 ohm

or less resistance between the

ground lug

on

the

external power cable plug and

the metal

frame.

 

 

 

 

13. Perform the following checks on each device that has its own power cables:

a. Check for damage to the power cord.

b. Check for the correct grounded power cable.

c. With

the external power cable connected to the device, check for 0.1 ohm or

less

resistance between the ground lug on the external power cable the

metal frame of the device.

14. Install

the covers.