IBM SA38-0512-03 manual Does, Stop With

Models: SA38-0512-03

1 253
Download 253 pages 34.64 Kb
Page 50
Image 50

Step 1240-4

One

of

the

FRUs

 

remaining

in

the

system unit

is

defective.

1. Power

off

the

system.

Refer

to

"Powering

Off

the

System".

2. Exchange

the

following

FRUS in

the

order

listed:

 

 

 

a. System Board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b. Power Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Power

on

the

system. Refer to "Powering On

the

System".

Does

the

system

stop

with

a

memory

 

checkpoint

displayed

on

the

operator

 

 

panel?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

Go

to"MAP

0410:

Repair

Checkout" in

theDiagnostics

Information for

 

 

Multiple

Bus

Systems.

 

 

 

 

 

 

 

 

 

 

YES

 

Reinstall

the

original

FRU.

 

 

 

 

 

 

 

 

 

Repeat this step until the defective

FRU

is

identified or all the FRUs have

 

 

been

exchanged.

 

 

 

 

 

 

 

 

 

 

 

 

 

If

the

symptom

did

not change

and

all

the FRUs have been exchanged,

 

 

go

to

“MAP

 

1540:

Minimum

Configuration”

on

page 2-21.

2-147043 43P Series Service Guide

Page 50
Image 50
IBM SA38-0512-03 manual Does, Stop With