Intel ZT 7102 manual String Response Formats Sheet 2, 111

Models: ZT 7102

1 152
Download 152 pages 43.02 Kb
Page 111
Image 111

Intel® NetStructureTMZT 7102 Chassis Management Module

RPC

Table 47. String Response Formats (Sheet 2 of 4)

Dataitem

Return format

Example

 

 

 

 

List of human-readable health events. Lines

Major Event: Fan Tray 3 Pres Fan

 

Tray Removed

 

are separated by line feeds with a

 

Major Event: FANTK9 Lower critical

 

null-terminator at the end.

 

"(null)” or "" if there are no healthevents

going low asserted

 

Major Event: FANTK8 Lower critical

healthevents

Refer to Section 11.0, “Health Event Strings”

going low asserted

 

on page 67

Major Event: FANTK7 Lower critical

 

Syntax:

 

going low asserted

 

[Critical/Major/Minor] Event: [Health String]

 

Minor Event: BP +12V Upper

 

/n /0

 

non-critical going high asserted

 

 

 

 

 

 

 

presence

 

 

listtargets

 

 

listdataitems

 

 

health

 

 

healthevents

 

List of available dataitems. Lines are

sel

 

 

 

separated by line feeds and a null-terminator

snmpenable

ListDataItems

at the end.

snmptrapcommunity

Syntax:

 

snmptrapaddress1

 

 

 

[Dataitem] /n /0

snmptrapaddress2

 

 

 

 

snmptrapaddress3

 

 

snmptrapaddress4

 

 

snmptrapaddress5

 

 

redundancy

 

 

powerstate

 

 

 

 

List of available targets. Targets represent

Brd Temp

 

the sensor data records (SDRs) for a

 

 

 

particular component. Lines are separated

+1.5 V

ListTargets

by line feeds with a null-terminator at the

+2.5 V

end.

 

+3.3 V

 

Syntax:

 

+5 V

 

[Sensor Name] /n /0

 

 

 

 

 

 

Null-terminated string containing the

 

 

user-specified physical location of the CMM,

 

location

16 characters maximum.

Server room 3

Syntax:

 

 

 

[Location String] /0

 

 

 

 

 

Human readable powerstate information

 

 

containing the target blade powerstate

 

 

information. Lines are separated by line

 

 

feeds with a null-terminator at the end.

Board is present

 

Syntax:

 

Board HEALTHY# signal is asserted

 

 

powerstate

Board is [present or not present] /n

Board has been powered up by the

 

Board HEALTHY# signal is [asserted or not

CMM

 

asserted /n

Board is in active mode.

 

 

 

Board has [not] been powered up by the

 

 

CMM /n

 

 

Board is in [active or offline] mode. /n /0

 

 

 

 

Technical Product Specification

111

Page 111
Image 111
Intel ZT 7102 manual String Response Formats Sheet 2, 111