Intel manual Introduction, Overview, ZT 7102 Features

Models: ZT 7102

1 152
Download 152 pages 43.02 Kb
Page 13
Image 13

Intel® NetStructureTMZT 7102 Chassis Management Module

Introduction

1.0Introduction

1.1Overview

The Intel® NetStructureTM ZT 7102 is a 3U, single-slot Chassis Management Module (CMM) intended for use with PICMG* 2.1, 2.16, and 2.9-compliant systems (the CompactPCI* Hot Swap, Packet Switching Backplane, and System Management specifications, respectively). This document details the features and specifications of the ZT 7102.

The ZT 7102 plugs into a dedicated slot in compatible systems. It provides centralized management and alarming for up to 21 node and/or fabric slots as well as for system power supplies and fans. The ZT 7102 may be paired with a backup for use in high-availability applications.

The ZT 7102 is a special purpose single board computer with its own CPU, memory, PCI bus, operating system, and peripherals. The ZT 7102 monitors and configures Intelligent Platform Management Interface (IPMI)-based components in the chassis. When thresholds such as temperature and voltage are crossed or a failure occurs, the CMM captures these events, stores them in an event log, sends SNMP traps, and drives the Telco alarm relays and alarm LEDs. The CMM can query FRU information (such as serial number, model number, manufacture date, etc.), detect presence of components (such as fan tray, CPU board, etc.), and perform health monitoring of each component. In addition, the CMM controls the power-up sequencing of each node board and the power to each slot via the BD_SEL# signal.

The ZT 7102 can also be used at a limited degree to manage non-IPMI based chassis components.

1.2ZT 7102 Features

High-density 3U X 1-slot form factor

Compatible with PICMG* 2.1, 2.16, and 2.9-compliant chassis and components

Monitors via the Intelligent Platform Management Bus (IPMB) protocol

Provides isolated IPMB signals for each slot for maximum security and reliability

Manage through the command line interface, SNMP v1/v3, or Remote Procedure Call (RPC)

Hot-add/hot-swap support for IPMI-based, field-replaceable components

µDB15 Telco Alarm Interface at the front panel

Critical, Major, and Minor alarm LEDs at the front panel

CMM status and hot swap LEDs at the front panel

Monitors backplane voltages and status for up to eight power supplies

Monitors system temperature sensors

Monitors system fan tray presence

Monitors tachometers for up to 16 system fans

Monitors sensors on PICMG 2.9 compliant single board computers

Power state control for single board compute blades

Technical Product Specification

13

Page 13
Image 13
Intel manual Introduction, Overview, ZT 7102 Features