Intel® NetStructureTMZT 7102 Chassis Management Module

 

 

 

Health Event Strings

Table 31. BIST Event Strings (BIST) (Sheet 2 of 2)

 

 

 

 

 

 

 

 

 

Event String

Event Code

 

Event Severity

 

 

 

 

 

 

"FRU unreadable!"

189

 

Critical

 

 

 

 

 

 

"RTC battery power lost."

190

 

Critical

 

 

 

 

 

 

"I2C failure while reading RTC."

191

 

Critical

 

 

 

 

 

 

"Primary FRU is corrupted."

272

 

Major

 

 

 

 

 

 

"Secondary FRU is corrupted."

273

 

Major

 

 

 

 

 

 

"FRU is corrupted!"

274

 

Critical

 

 

 

 

 

Table 32.

Telco Alarm Sensor Event Strings (TASensor[1,2])

 

 

 

 

 

 

Event String

Event Code

Event Severity

 

 

 

 

 

“asserted.”

96

Major

 

 

 

 

 

“deasserted.”

97

OK

\

 

 

 

 

 

 

Table 33.

LAN Sensor Event Strings (Eth[0,1,1:1] Interface)

 

 

 

 

 

 

Event String

Event Code

Event Severity

 

 

 

 

 

“Duplicate IP address detected on the network.”

84

Major

 

 

 

 

 

“Duplicate IP address corrected.”

85

OK

 

 

 

 

11.4.4Chassis Location

Table 34. Fan Tray Presence Event Strings (Fan Tray [1-3] Presence)

Event String

Event Code

Event Severity

 

 

 

"Fan Tray Removed"

64

Major

 

 

 

"Fan Tray Inserted"

65

OK

 

 

 

Table 35. Chassis Power Supply Event Strings (Pwr Supply N)

Event String

Event Code

Event Severity

 

 

 

"Recovered from error conditions"

48

OK

 

 

 

"Power Supply Failure detected"

49

Critical

 

 

 

"Power Supply Degraded"

50

Minor

 

 

 

“Power Supply detected”

53

OK

 

 

 

“Power Supply removed”

54

Major

 

 

 

Note: Chassis power supply detected and removed events are only generated with IPMI power supplies.

Technical Product Specification

73

Page 73
Image 73
Intel ZT 7102 manual Chassis Location