Intel® NetStructureTMZT 7102 Chassis Management Module

RPC

Table 48. Integer Response Formats (Sheet 2 of 2)

Dataitem

 

Return format

Example

 

 

 

 

Integer returned is a 1 or 0.

 

psinhibit

1 = Power supply is not inhibited

1

 

0

= Power supply is inhibited

 

 

 

 

 

Integer value indicating SNMP status:

 

snmpenable

0

= disabled

0

 

1

= enabled

 

 

 

 

 

20.2.6FRU String Response Format

Querying an individual FRU field returns a null terminated string with a single line feed. Querying individual FRU areas returns a null terminated string with the following:

Board Area:

3 Linefeeds

Product Area:

2 Linefeeds

Chassis Area:

2 Linefeeds

Querying the entire FRU (all) will return all of the above areas present in the FRU with the line feeds listed above.

Table 49. FRU Data Items String Response Format (Sheet 1 of 2)

Data Item

Description

 

 

all

Null-terminated string containing all FRU information for the location

 

 

boardall

Null-terminated string containing all board area FRU information for the

location

 

 

 

boarddescription

Null-terminated string containing the description field in the FRU board area

for the location

 

 

 

boardmanufacturer

Null-terminated string containing the manufacturer field in the FRU board

area for the location

 

 

 

boardpartnumber

Null-terminated string containing the part number field in the FRU board area

for the location

 

 

 

boardserialnumber

Null-terminated string containing the serial number field in the FRU board

area for the location

 

 

 

boardmanufacturedatetime

Null-terminated string containing the manufacture date and time field in the

FRU board area for the location

 

 

 

productall

Null-terminated string containing the product area FRU information for the

location

 

 

 

productdescription

Null-terminated string containing the description field in the FRU product area

for the location

 

 

 

productmanufacturer

Null-terminated string containing the manufacturer field in the FRU product

area for the location

 

 

 

productmodel

Null-terminated string containing the model field in the FRU product area for

the location

 

 

 

productpartnumber

Null-terminated string containing the part number field in the FRU product

area for the location

 

 

 

114

Technical Product Specification

Page 114
Image 114