Intel® NetStructureTMZT 7102 Chassis Management Module
RPC
Table 45. Error and Return Codes for the RPC Interface (Sheet 2 of 4)
Code #: | Error Code String | Error Code Description |
|
|
|
34 |
| An IPMI request returned with a non |
| E_IMB_COMPCODE_ERROR | successful completion code. User should |
|
| try the command again. |
|
|
|
35 | E_IMB_INVALID_PACKET | Invalid IPMI response. Blade may be |
| returning invalid data. | |
|
| |
|
|
|
36 | E_IMB_INVALID_REQUEST | Invalid IPMI response. Blade may be |
| returning invalid data. | |
|
| |
|
|
|
37 | E_IMB_RESPONSE_DATA_OVERFLOW | Invalid IPMI response. Blade may be |
| returning invalid data. | |
|
| |
|
|
|
38 | E_IMB_DATA_COPY_FAILED | Internal CMM Error |
|
|
|
39 | E_IMB_INVALID_EVENT | Internal CMM Error |
|
|
|
40 | E_IMB_OPEN_DEVICE_FAILED | Internal CMM Error |
|
|
|
41 | E_IMB_MMAP_FAILED | Internal CMM Error |
|
|
|
42 | E_IMB_MUNMAP_FAILED | Internal CMM Error |
|
|
|
43 | E_IMB_RESP_LEN_ERROR | Invalid IPMI response. Blade may be |
| returning invalid data. | |
|
| |
|
|
|
44 | E_NEM_SNMPTRAP_ERROR | Error setting snmptrap parameters. Retry |
| command | |
|
| |
|
|
|
45 | E_NEM_SYSTEMHEALTH_ERROR | Internal CMM Error |
|
|
|
46 | E_NEM_GETHEALTH_ERROR | Internal CMM Error |
|
|
|
47 | E_NEM_SNMPENABLE_ERROR | Internal CMM Error |
|
|
|
48 | E_NEM_SENSOR_HEALTH_ERROR | Internal CMM Error |
|
|
|
49 | E_NEM_FILTER_SEL_ERROR | Internal CMM Error |
|
|
|
50 | E_NEM_INITIALIZE_ERROR | Internal CMM Error |
|
|
|
51 | E_NEM_SENSOR_EVENT | Internal CMM Error |
|
|
|
52 | E_NEM_SENSOR_ERROR | Internal CMM Error |
|
|
|
53 | E_NEM_SNMP_PROCESS_EVENT_ERROR | Internal CMM Error |
|
|
|
54 | E_NEM_SNMP_DEST_ADDR_ERROR | SNMP Trap address that the user is setting |
| is invalid | |
|
| |
|
|
|
55 | E_NEM_SNMP_COMMUNITY_STRING_ERROR | SNMP Community that user is setting is |
| invalid | |
|
| |
|
|
|
56 | E_NEM_SNMP_TRAP_VERSION_ERROR | SNMP Trap version that the user is setting |
| is invalid | |
|
| |
|
|
|
57 | E_NEM_SNMP_TRAP_PORT_ERROR | SNMP Trap port that the user is setting is |
| invalid | |
|
| |
|
|
|
58 | E_NEM_SNMP_CFG_ERROR | Cannot read SNMP config parameter. |
| Config file may be corrupted. | |
|
| |
|
|
|
59 | E_NEM_SEND_SNMP_TRAP_ERROR | Internal CMM Error |
|
|
|
60 | E_SFS_INVALID_TRANSACTION | Internal CMM Error |
|
|
|
61 | E_SFS_LOCK_SDR | Can't read SDRs. Blade may be busy, try |
| again. | |
|
| |
|
|
|
62 | E_SFS_ENTITY_ID | Internal CMM Error |
|
|
|
63 | E_SFS_DEVICE_LOCATOR_NULL | Internal CMM Error |
|
|
|
Technical Product Specification | 107 |