Intel ZT 7102 manual Enabling Power Supplies

Models: ZT 7102

1 152
Download 152 pages 43.02 Kb
Page 84
Image 84

Intel® NetStructureTMZT 7102 Chassis Management Module

Power Supplies

13.5Inhibiting Power Supplies

Power supplies can be inhibited through the CMM. This is accomplished using the following command:

cmmset -l chassis -d psinhibitN -v 0

Where N is the number of the power supply that is to be inhibited.

Note: When a non-IPMI supply is inhibited, a SEL entry is logged indicating a failure condition. When the non-IPMI supply is enabled a SEL entry is logged indicating that the power supply has recovered from a failure condition. This does not occur in current IPMI-compliant power supplies.

13.6Enabling Power Supplies

To enable a supply which has been inhibited, issue the following command:

cmmset -l chassis -d psinhibitN -v 1

Where N is the number of the power supply that is to be enabled.

Note: When a non-IPMI supply is enabled a SEL entry is logged indicating that the power supply has recovered from a failure condition. This is because when a non-IPMI supply is inhibited, a SEL entry is logged indicating a failure condition. This does not occur in current IPMI-compliant power supplies.