Intel® NetStructureTMZT 7102 Chassis Management Module

Command Line Interface (CLI) Syntax and Arguments

Table 26. dataitem (-d) Keywords for Chassis Location

Data Item

Description

Get/

Valid Set Values:

Set

 

 

 

 

 

 

 

 

Used to set or query the fan speed of all the fans in

 

 

 

the system as a percentage of their full speed. Some

 

 

 

fan trays may prevent the fan speed from going to

 

 

 

zero. Querying the fan speed does not show actual

 

100 (default)

 

fanspeed, but reflects what the CMM fan speed output

 

fanspeed

is set to as a percentage of the actual full fan speed.

Both

80

 

See Section 17.0, “Fan Control and Monitoring” on

 

0

 

page 91 for further information.

 

 

 

 

 

Note: In case of a temperature upper threshold

 

 

 

violation, the fans will be automatically set by the

 

 

 

CMM to run at full speed until the violation deasserts.

 

 

 

 

 

 

 

Used to set or query the value configured in the CMM

 

2 (default)

healthyrampuptime

for the maximum amount of time the CMM will wait for

Both

through 60

 

the HEALTHY # hardware signal to be asserted by an

 

in seconds

 

SBC.

 

 

 

 

 

 

 

 

 

Used to set or query the location field in the chassis

 

Location String of

location

Both

up to 16

FRU.

 

 

characters

 

 

 

 

 

 

 

 

Used to set or query the value for the maximum

 

-1” (Default)

 

 

0

maxpowerupattempts

number of tries the CMM will attempt to power up a

Both

through

 

board during the power sequencing loop.

 

 

 

 

2000000000

 

 

 

 

psinhibit[1..8]

Used to inhibit the power supplies in the chassis.

Both

1 - Enable

0- Inhibit

 

 

 

 

 

 

 

 

Queries chassis slot layout information. This will tell

 

 

slotinfo

the user what slots are system slots, peripheral slots,

Get

N/A

or busless slots. It will also show which slots are

 

 

 

 

occupied by blades.

 

 

 

 

 

 

Table 27. dataitem (-d) Keywords for CMM Location (Sheet 1 of 2)

Data Item

Description

Get/

Valid Set

Set

Values:

 

 

 

 

 

 

 

Used to engage the Alarm Cutoff (ACO) or get its value.

 

1 - Set cut off

 

When engaged, the ACO silences active alarms and

 

alarmcutoff

Both

0 - Unset cut

blinks the alarm LEDs on the CMM. This Dataitem is

 

 

off

 

only valid when used with the CMM as the location.

 

 

 

 

 

 

 

 

 

Used to set the Alarm Cutoff timeout value (in minutes)

 

Number of

 

or get its value. This is the length of time the CMM waits

 

minutes:

alarmtimeout

before automatically canceling an engaged ACO (if the

Both

0-1000.

user fails to cancel it manually). A value of 0 disables the

Value of 0

 

 

 

timeout. This dataitem is only valid when used with the

 

disables the

 

CMM as the location.

 

timeout.

 

 

 

 

criticalled

 

 

1 - Turn On

 

 

LED

minorled

Used to turn on or off the critical, major and minor LEDs.

Set

0 - Turn Off

majorled

 

 

 

 

LED

 

 

 

 

 

 

 

Ethernet

Used to change to the eth0 direction to either the front

Both

front (default)

panel or the rear panel IO card.

rear

 

 

 

 

 

 

60

Technical Product Specification

Page 60