Intel ZT 7102 manual CMM File Sync Event Strings CMM File Sync, Chassis Sensor Event Strings

Models: ZT 7102

1 152
Download 152 pages 43.02 Kb
Page 75
Image 75

Intel® NetStructureTMZT 7102 Chassis Management Module

 

 

 

Health Event Strings

Table 38. CMM Failover Event Strings (CMM Failover)

 

 

 

 

 

 

 

 

 

Event String

Event Code

 

Event Severity

 

 

 

 

 

 

"Failover occurred because the other CMM rebooted."

223

 

OK

 

 

 

 

 

 

"Failover cannot occur because the other CMM has a bad switch."

224

 

OK

 

 

 

 

 

 

"Failover cannot occur because the other CMM has lost network

225

 

OK

 

connectivity with its Primary SNMP trap destination."

 

 

 

 

 

 

 

 

 

 

 

"Failover cannot occur because the other CMM has critical health

226

 

OK

 

events."

 

 

 

 

 

 

 

 

 

 

 

"Failover cannot occur because the other CMM is not responding

227

 

OK

 

over its management bus."

 

 

 

 

 

 

 

 

 

 

 

"Failover cannot occur because the critical items have not been

228

 

OK

 

synced."

 

 

 

 

 

 

 

 

 

 

 

“Failover cannot occur becausehet other CMM has a bad hardware

229

 

OK

 

signal.”

 

 

 

 

 

 

 

 

 

 

 

“Failover occurred because the active CMM had older firmware than

240

 

OK

 

the newly active CMM.”

 

 

 

 

 

 

 

 

Note: In the CMM Redundancy and Failover event strings, the phrases “bad switch” and “switch failure” refer to the switch that is associated with that CMM having deasserted its HEALTHY# signal. The “bad hardware signal” refers to the CMM itself having deasserted its HEALTHY# signal.

Table 39. CMM File Sync Event Strings (CMM File Sync)

Event String

Event Code

If HealthEvents, its

severity

 

 

 

 

 

"Could not copy the /etc/CMM.cfg file to the standby CMM."

230

OK

 

 

 

"Could not copy the /etc/passwd and /etc/shadow files to the standby

231

OK

CMM."

 

 

 

 

 

“Default password files synced to active CMM. Passwords have been

232

OK

reset to default.”

 

 

 

 

 

"Could not copy the /etc/sel_* files to the standby CMM."

233

OK

 

 

 

"Could not copy the /etc/snmpd.conf and /etc/var/snmpd.conf files to

234

OK

the standby CMM."

 

 

 

 

 

"Could not copy the SDR file to the standby CMM."

235

OK

 

 

 

"Could not copy the /etc/scripts directory to the standby CMM."

236

OK

 

 

 

"All files successfully synced."

237

OK

 

 

 

Table 40. Chassis Sensor Event Strings

Event String

Event Code

Event Severity

 

 

 

“No PCI connectivity record found in chassis FRU information.”

256

Critical

 

 

 

“cmm.sif file not found. Cannot scan CMM sensors.”

257

Critical

 

 

 

“chassis.sif file not found. Cannot scan Chassis sensors.”

258

Critical

 

 

 

Technical Product Specification

75

Page 75
Image 75
Intel ZT 7102 manual CMM File Sync Event Strings CMM File Sync, Chassis Sensor Event Strings