9.Open the ejector latch on the standby CMM and wait for the blue hot swap LED to illuminate, indicating the CMM is safe to remove from the system.

10.A health event will occur on the active CMM indicating redundancy has been lost. A SEL entry will be recorded, and a trap will be sent out.

11.Remove the standby CMM from the chassis.

12.Turn off the dip switch SW1-1.

13.Reinsert the CMM into the system and allow the CMM to fully boot into Bluecat Linux.

14.The password can now be set on the active CMM and it will get synched to the standby CMM and the CMM can now be operated normally.