Intel® NetStructureTMZT 7102 Chassis Management Module

Example CLI Commands

Appendix D Example CLI Commands

The following table shows examples of most CLI operations.

Note: The variable “N” (as in bladeN or fantrayN) represents the chassis slot number of the device being acted on (such as Blade5 or fantray1). Please refer to chassis documentation for slot, fan, fan tray, and power supply location and information.

Table 55. Example CLI Commands (Sheet 1 of 2)

Use Case

CLI Command

Return

 

 

 

Get current chassis

cmmget –l chassis –t “Temp Snsr 1”

Current Temperature for “Temp

temperature for “Temp

–d current

Sensr 1” on chassis.

Snsr 1”.

 

 

 

 

 

Get fan tray 1

cmmget –l fantray1 –d presence

Fantray1 is present.

presence.

Fantray1 is not present.

 

 

 

 

Get the baseboard

 

 

temperature of blade

 

Current Temperature of “ambient

5 when the sensor is

cmmget –l blade5 –t “ambient temp”–d current

temp” on blade 15.

named “ambient

 

 

 

temp”.

 

 

 

 

 

Find out if blade 15 is

cmmget –l blade15 –d presence

Blade15 is present.

present.

Blade15 is not present.

 

 

 

 

 

 

Returns thresholds for upper

Get all thresholds for

 

non-recoverable, upper critical,

the +3.3 V sensor on

cmmget –l blade2 –t “+3.3V” –d thresholdsall

upper non-critical, lower

blade 2.

 

non-critical, lower critical, and lower

 

 

non-recoverable.

 

 

 

Get the overall system

cmmget –l system –d health

Indicates if the entire system is

health.

healthy, or has health events.

 

 

 

 

Get a list of blades

cmmget –l system –d unhealthylocations

List of locations with active health

with problems

events.

 

 

 

 

Get the CMM’s overall

 

Indicates if the CMM is healthy or if

cmmget –l cmm –d health

there are active health events on

health.

 

the CMM.

 

 

 

 

 

Display the SEL of the

cmmget –l cmm –d sel

Displays a list of SEL entries (if any)

CMM

for the CMM.

 

 

 

 

Display the SEL of

cmmget –l blade19 –d sel

Displays a list of SEL entries (if any)

blade19.

for blade 19.

 

 

 

 

Get the version of

cmmget –l cmm –d version

Displays the version of firmware

firmware on the CMM

currently installed on the CMM.

 

 

 

 

Power off blade 19.

cmmset -l blade19 d powerstate –v poweroff

Displays a success or failure

message.

 

 

 

 

 

Power on blade 20.

cmmset –l blade20 d powerstate –v poweron

Displays a success or failure

message.

 

 

 

 

 

Reset blade 3.

cmmset –l blade3–d powerstate -v reset

Displays a success or failure

message.

 

 

 

 

 

Get all of the chassis

cmmget –l chassis -t fru -d all

Displays a list of all of the FRU

FRU information.

information from the chassis.

 

 

 

 

Get all fantray2 FRU

cmmget –l fantray2 –t fru –d all

Displays a list of all of the FRU

information

information from the CMM.

 

 

 

 

Technical Product Specification

139

Page 139
Image 139
Intel ZT 7102 manual Example CLI Commands Sheet 1, 139, Use Case CLI Command Return