Health Event Strings
11.4.3 | CMM Location |
|
|
Table 31. BIST Event Strings (BIST) (Sheet 1 of 2) |
|
| |
|
|
|
|
| Event String | Event Code | Event Severity |
|
|
|
|
| “Boot is Successful.” | 112 | OK |
|
|
|
|
| 113 | Critical | |
|
|
|
|
| “RedBoot image corrupted.” | 114 | Major |
|
|
|
|
| “Backup RedBoot imagecorrupted.” | 115 | Critical |
|
|
|
|
| “FPGA image corrupted. Using backup image.” | 116 | Major |
|
|
|
|
| “Backup FPGA image corrupted.” | 117 | Critical |
|
|
|
|
| “OS image corrupted.” | 118 | Critical |
|
|
|
|
| “Base memory test failed.” | 119 | Critical |
|
|
|
|
| “Extended memory test failed.” | 120 | Critical |
|
|
|
|
| “FPGA1 firmware outdated.” | 121 | Minor |
|
|
|
|
| “FPGA2 firmware outdated.” | 122 | Minor |
|
|
|
|
| “FPGA 1+2 version mismatched.” | 123 | Minor |
|
|
|
|
| “RTC date is invalid.” | 124 | Major |
|
|
|
|
| “RTC time is invalid.” | 125 | Major |
|
|
|
|
| “RTC is not working.” | 126 | Critical |
|
|
|
|
| “One of the Ethernet interfaces is not working.” | 127 | Minor |
|
|
|
|
| “Both Ethernet interfaces are not working.” | 128 | Major |
|
|
|
|
| “CMM Boot.” | 129 | OK |
|
|
|
|
| “IPMB bus | 130 - 159 | Major |
|
|
|
|
| “Software update successful.” | 160 | OK |
|
|
|
|
| “Update of RedBoot failed.” | 161 | Critical |
|
|
|
|
| “Update of FPGA failed.” | 162 | Critical |
|
|
|
|
| “Update of Bluecat OS failed.” | 163 | Critical |
|
|
|
|
| “Update of /etc failed.” | 164 | Critical |
|
|
|
|
| “Restore of /etc files failed.” | 165 | Critical |
|
|
|
|
| “Software update failed.” | 166 | Critical |
|
|
|
|
| “Standby CMM has completed FPGA | 179 | OK |
|
|
|
|
| “FPGA | 180 | Minor |
|
|
|
|
| “FPGA | 181 | Minor |
|
|
|
|
| “FPGA | 182 | Critical |
|
|
|
|
| “FPGA | 183 | Critical |
|
|
|
|
| “Dynamic FLASH image corruption detected.” | 184 | Critical |
|
|
|
|
| “Static Redboot image is corrupt.” | 185 | Critical |
|
|
|
|
| “Static OS image is corrupt.” | 186 | Critical |
|
|
|
|
| “Static FPGA image is corrupt.” | 187 | Critical |
|
|
|
|
| “Primary FRU unreadable - using Secondary" | 188 | Minor |
|
|
|
|