Intel® NetStructureTMZT 7102 Chassis Management Module
Command Line Interface (CLI) Syntax and Arguments
8.4Target Parameter: -t
The Target parameter is the sensor or variable that the cmmget or cmmset acts on. The Target keywords are shown in the following table.
Note: If the target is not specified, then it is assumed that Dataitem is an attribute of Location.
Table 22. Target (-t) Keywords
Keyword | Description | |
|
| |
| Used to query the FRU or individual FRU fields for a specific location. For more | |
fru | information on querying a component’s FRU and individual FRU fields, see Section 16.0, | |
| “Obtaining FRU Information” on page 89. | |
|
| |
SDR Sensors | The sensor name as defined in its Sensor Data Record (SDR) for that component. Sensor | |
names can be retrieved for an IPMI based location using the ListTargets Dataitem. | ||
| ||
|
| |
none | Same as not entering a target. | |
|
|
8.5Dataitem Parameter: -d
The Dataitem parameter is the Target or Location attribute that the user is getting or setting. Dataitem must be given for every CLI command. The Dataitem keywords are shown in the following table.
Table 23. dataitem (-d) Keywords for All Locations (Sheet 1 of 2)
Data Item | Description | Get/ | Valid Set | |
Set | Values: | |||
|
| |||
|
|
|
| |
| Used to configure user defined actions when events occur. |
|
| |
| This dataitem is used with a target |
| Valid filename | |
criticalaction | sensor and a value |
| ||
| of a script that | |||
majoraction | happens for that particular sensor, then the script defined |
| ||
| resides in | |||
in the | Both | |||
| ||||
minoraction |
| |||
executed must be located in the /home/scripts directory on |
| /home/scripts | ||
|
| |||
normalaction | the CMM and the /home/scripts path should be omitted |
| none | |
| when specifying the script. See Section 18.0, “CMM |
| ||
|
|
| ||
| Scripting” on page 93 for more information. |
|
| |
|
|
|
| |
current | The current value of a sensor. | Get | N/A | |
|
|
|
| |
health | Returns the health of the location and if any events exist. | Get | N/A | |
|
|
|
| |
healthevents | Returns the specific health events that are occurring on | Get | N/A | |
the location if any exist. | ||||
|
|
| ||
|
|
|
| |
listdataitems | Used to find the data items available on a location. | Get | N/A | |
The output lists dataitems that the location supports. | ||||
|
|
| ||
|
|
|
| |
| Used to find what sensors or targets are available on the |
|
| |
listtargets | location. This is the list of sensors defined by the SDR for | Get | N/A | |
| that particular location. |
|
| |
|
|
|
| |
| Used to find out if a particular location is occupied or |
|
| |
presence | present in the chassis. This can be blades or intelligent fan | Get | N/A | |
| trays. |
|
| |
|
|
|
| |
sel | Returns a location's System Event Log. | Get | N/A | |
|
|
|
|
58 | Technical Product Specification |