Juniper Networks E-Series manual Installation Guidelines and Requirements

Models: E-Series

1 242
Download 242 pages 28.32 Kb
Page 140
Image 140

11-4CHAPTER 11 System Specifications

Table 11-2ERX-7xx models specifications (continued)

Category

Specification

Airflow

• Airflow direction is in through the right side and out through the left side. See

 

Figure 3-2in Chapter 3, Installation Guidelines and Requirements.

DC Input

 

Voltage

–40 to –72 VDC

Current

30 A @ –48 VDC

Power

1400 W maximum

Redundancy (input power)

2 independent line feeds

 

 

NEBS Certification

SR-3580 (FD-15): Network Equipment Building System (NEBS) Criteria

 

Levels, Issue 1, November 1995

 

GR-63 (LSSGR, FD-15): Network Equipment Building System (NEBS)

 

Requirements: Physical Protection, Issue 1, October 1995

 

GR-1089 (LSSGR, FD-15):Electromagnetic Compatibility and Electrical

 

Safety - Generic Criteria for Network Telecommunications Equipment, Issue

 

2, Revision 1, February 1999

Safety Agency Certification

AS/NZS 3260:1993, Safety of Information Technology Equipment Including

 

Electrical Business Equipment

 

CAN/CSA C22.2, No. 60950-00, 3rd Edition, Safety of Information

 

Technology Equipment

 

EN60825-1, Safety of Laser Products - Part 1: Equipment Class,

 

Requirements, and User’s Guide (2001)

 

EN60950:2000, 3rd Edition, Safety of Information Technology Equipment

 

IEC 60950-1(2001-10) Ed. 1.0 Information technology equipment - Safety -

 

Part 1: General requirements

 

Low Voltage Directive (73/23/EEC)

 

UL 60950, 3rd Edition, Safety of Information Technology Equipment

 

 

Electromagnetic Emissions

AS/NZS 3548:1995 (CISPR 22 Class A)

Agency Certification

EMC Directive (89/336/EEC)

 

EN55022 Class A (CISPR-22 Class A)

 

EN55024, Annex C for WAN Equipment Performance Criteria A, B, and C

 

ETSI 300-386, Telecommunication Network Equipment; ElectroMagnetic

 

Compatibility (EMC) requirements

 

FCC Part 15 Class A

 

IECS-003 Issue 3 Class A

 

VCCI (Voluntary Control Council for Interference by Information Technology

 

Equipment)

 

 

Page 140
Image 140
Juniper Networks E-Series manual Installation Guidelines and Requirements