Juniper Networks E-Series manual CT1 and CE1 I/O Modules, DB-9 Pin Signal RJ-45 Pin

Models: E-Series

1 242
Download 242 pages 28.32 Kb
Page 208
Image 208

A-4

APPENDIX A Cable Pinouts

Table A-3DB-9RJ-45 crossover adapter pinout

DB-9 Pin

Signal

RJ-45 Pin

1

DCD

1

 

 

 

2

RXD

3

 

 

 

3

TXD

2

 

 

 

4

DTR

6

 

 

 

5

GND

5

 

 

 

6

DSR

4

 

 

 

7

RTS

8

 

 

 

8

CTS

7

 

 

 

9

RNG

n/ca

a. n/c=no connect

Table A-4lists the pinout for the straight-through adapter.

Table A-4DB-9RJ-45 straight-through adapter pinout

DB-9 Pin

RS-232 Signal Name

RJ-45 Pin

Ethernet Signal Name

1

DCD

1

TX +

 

 

 

 

2

RXD

2

TX –

 

 

 

 

3

TXD

3

RX +

 

 

 

 

4

DTR

4

n/ca

5

GND (signal)

5

n/c

 

 

 

 

6

DSR

6

RX –

 

 

 

 

7

RTS

7

n/c

 

 

 

 

8

CTS

8

n/c

 

 

 

 

9

RNG

n/c

none

 

 

 

 

a. n/c=no connect

CT1 and CE1 I/O Modules

CT1 I/O modules have 24 RJ-48C female connectors. CE1 I/O modules have either 20 RJ-48C female connectors or two 25-pair female Telco connectors. Figure A-3shows the location of the ports on a CT1 I/O module and the sequence of the pins in the RJ-48C connector. CE1 I/O modules equipped with RJ-48C connectors have the same configuration as CT1 I/O modules equipped with RJ-48C connectors.