11-6

CHAPTER 11 System Specifications

Table 11-3ERX-310 router specifications (continued)

Category

Specification

Space Requirements

• 3 feet (90 cm) behind router or rack

 

• Do not block air vents on sides of the router.

 

• Do not place equipment that exhausts hot air to left on the right of the

 

router.

 

• Be aware that router exhausts hot air from its left side.

 

 

Airflow

• Airflow direction is in through the right side and out through the left side.

 

See Figure 3-2in Chapter 3, Installation Guidelines and Requirements.

DC Input

 

Voltage

–40 to –72 VDCa

Current

9 A @ –48 VDC

Power

500 W maximum

Redundancy (input power)

2 independent line feeds

 

 

AC Input

 

Power required

90-265 VAC @ ~5 A

AC line frequency

50-60 Hz

Power

500 W

 

 

NEBS Certification

Not yet available for the ERX-310 router

Safety Agency Certification

AS/NZS 3260:1993, Safety of Information Technology Equipment

 

Including Electrical Business Equipment

 

CAN/CSA C22.2, No. 60950-00, 3rd Edition, Safety of Information

 

Technology Equipment

 

EN60825-1, Safety of Laser Products - Part 1: Equipment Class,

 

Requirements, and User’s Guide (2001)

 

EN60950:2000, 3rd Edition, Safety of Information Technology

 

Equipment

 

IEC 60950-1(2001-10) Ed. 1.0 Information technology equipment -

 

Safety - Part 1: General requirements

 

Low Voltage Directive (73/23/EEC)

 

UL 60950, 3rd Edition, Safety of Information Technology Equipment

 

 

Electromagnetic Emissions

AS/NZS 3548:1995 (CISPR 22 Class A)

Agency Certification

EMC Directive (89/336/EEC)

 

EN55022 Class A (CISPR-22 Class A)

 

EN55024, Annex C for WAN Equipment Performance Criteria A, B, and

 

C

 

ETSI 300-386, Telecommunication Network Equipment;

 

ElectroMagnetic Compatibility (EMC) requirements

 

FCC Part 15 Class A

 

IECS-003 Issue 3 Class A

 

VCCI (Voluntary Control Council for Interference by Information

 

Technology Equipment)

 

 