CHAPTER 12
Module Specifications
12-16
I/O Module Specifications

See Tabl e 12-3 on the following pages for I/O module details such as module type, E-series model

compatibility, SRP module compatibility, number of ports, connector type, and cabling

specifications.

Table12-3 I/O module specifications
I/O Module LabelaType
Model
Compatibility
SRP Module
Compatibility
No. of
Ports Connector Type Cabling Specifications
CE1
CE1
FULL
I/O
Non-ASIC ERX-7xx models
ERX-1410 router
SRP-5G
SRP-5G+
SRP-10G
20 RJ-48C,120 ohm
BNC, 75 ohm via a
balun panel that
connects to the I/O
module
Use shielded cables to maintain
EMC compliance.
The transmitted signal complies
with ITUT G.703,
Physical/electrical characteristics
of hierarchical digital interfaces
(November 2001) for cable
lengths up to 450 m (492 yards).
cOC3/STM1
cOC3
STM1
F0 I/O
MULTI
MODE
ASIC ERX-7xx models
ERX-14xx models
ERX-310 router
SRP-5G+
SRP-10G
SRP-40G
SRP-40G+
SRP-SE10G
4SC full duplex •Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles) over
62.5-micron core cable with an
optical loss of 0–9 dB or
50-micron core cable with an
optical loss of 7 dB