Juniper Networks E-Series manual ERX-7xx Models Specifications, 11-3

Models: E-Series

1 242
Download 242 pages 28.32 Kb
Page 139
Image 139

ERX-7xx Models Specifications

E-Series Routers

Table 11-1ERX-14xx models specifications (continued)

Category

Specification

Telecommunications

ACA TS 016-1997

Certification

CTR13 – Commission Decision of 9 July 1997 on a common technical

 

 

regulation for attachment requirements for terminal equipment interface for

 

 

connection to 2048 kbit/s digital structured ONP leased lines: 97/521/EC –

 

 

OJ No. L215 Vol. 40, August 1997

 

CTR24 – Commission Decision of 9 September 1997 on a common

 

 

technical regulation for attachment requirements for terminal equipment

 

 

interface for connection to 34 Mbit/s digital unstructured and structured

 

 

leased lines: 97/639/EC – OJ No. L271 Vol. 40, 3 October 1997

 

FCC PART 68

 

IECS-003 Issue 3 Class A

 

PD7024 – Essential requirements for terminal equipment intended for

 

 

connection to unstructured digital leased circuits of the public

 

 

telecommunications network using a CCITT recommendation G,703

 

 

interface at a rate of 2048 kbit/s with a 75 ohm unbalanced presentation,

 

 

1994

 

RTTE Directive (1999/5/EEC)

 

 

 

11-3

a.If the voltage rises above –40 VDC, the system will power off. The system will not power on again until the input voltage reaches –43 +/– 0.5 VDC.

ERX-7xx Models Specifications

Table 11-2ERX-7xx models specifications

Category

Specification

Weight

 

 

Chassis only

22 lb

9.9 kg

Chassis fully configured

46 lb

20.7 kg

 

 

Dimensions

10.5 (H) x 19 (W) x 16 (D) inches; 26.67 x 48.26 x 40.64 cm

Environmental Requirements

NEBS GR-63-CORE compliant

Ambient operating temperature

• Long term: 41° to 104° F (5° to 40° C)

 

Short term: 23° to 122° F (–5°to 50° C)

Ambient operating humidity

• Long term: 5% to 85% (noncondensing)

 

Short term: 5% to 95% (noncondensing)

Ambient storage temperature

–40°to 158° F (–40°to +70° C), 95% relative humidity

Ambient storage humidity

5% to 95% (noncondensing)

 

 

Heat Dissipation

1400 W, 4780 BTU/hour maximum

Space Requirements

• 3 feet (90 cm) behind router or rack

 

• Do not block air vents on sides of the router.

 

• Do not place equipment that exhausts hot air to left on the right of the router.

 

• Be aware that router exhausts hot air from its left side.

 

 

 

Page 139