Empty SODIMM socket
SODIMM
g013452
Figure 9-3 SODIMM sockets on the SRP-40 module
2Insert a SODIMM from the upgrade kit at an angle of approximately 45 degrees into an empty ceramic connector, so that the notch in the long gold edge of the SODIMM aligns with the notch in the connector.
The notch on the long gold edge will no longer be visible when the
SODIMM is pressed in far enough.
3Press the top surface downward into the socket until the socket spring snaps into place and holds it.
4Repeat steps 2 through 3 with the other SODIMM.
5Repeat steps 1 through 4 for the other SRP module, if present.
Verifying the Upgrade
To verify that the upgrade is complete:
1Place the SRP modules in the chassis. The SRP modules will reboot.
2Close the ejector handles and tighten the thumbscrews.
3Issue the show hardware command, and verify that the display indicates that the correct amount of memory is present.