2-70 McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
Installation Tasks
To install and enable this option, select the Configure Feature Key
option under the element manager’s Configure menu. Refer to Task 16:
Configure PFE Key (Optional) on page 2-56.

Enabling and Configuring Open Trunking

To enable Open Trunking for a specific switch and configure
threshold values and event notification options, use the following
steps.
1. Select Open Trunking from the Configure menu on the menu bar.
The Configure Open Trunking dialog box displays.
Figure 2-63 Configure Open Trunking Dialog Box
2. Enable Open Trunking by clicking the Enable Open Trunking check
box to display a check mark.
3. Set the Congestion Thresholds for ports as percentages of link
bandwidths, in the range of 1% through 99%. These thresholds
are used only when a port becomes an ISL. When the link’s traffic
load becomes greater than this percentage, the link is seen as