3
MAP 0000: Start MAP 3-17
Diagnostics
23
Obtain event codes from the Sphereon 3032/3232 Event Log.
If multipl e event codes are fou nd, note all co des and associate d severity
levels . R ec ord the dat e, ti me , and listed seq uence, and d etermine if the
codes are related to the reported problem. Begin fault isolation with the
most rec ent even t code with the highe st sever ity level . Other c odes may
accompany this event code, or may indicate a normal indication after a
problem is recovered.
a. At the Hardware View, select Event Log from the Logs icon on
the navigati on con tr ol pan el. The Event Log displays.
b. Record the event code, date, time, and severity (Informational,
Minor, Major, or Severe).
c. Record all event codes that may relate to the reported problem.
Figure 3-6 Event Log
Were one or more event codes found?
NO YES
Go to Table 3-3 on page 3-3.
Return to the MAP step that sent you here.
24
Are you at the switch reporting the problem?
YES NO
Go to step 36.
25
Is the PWR LED at the switch front panel illuminated?
NO YES
Go to step 30.