2
Task 25: Configure the Switch from the SANpilot Interface (Optional) 2-121
Installation Tasks
e. Click the check box in the Write Authorization column to
enable or disable write authorization for the trap recipient
(default is disabled). A check mark indicates write
authorization is enabled. When the feature is enabled, a
management workstation user can change sysContact,
sysName, and sysLocation SNMP variables.
f. Type the IP address or DNS host name of the trap recipient
(SNMP management workstation) in the Trap Recipient field. It
is recommended the IP address be used.
g. The default UDP port number for trap recipients is 162. Type a
decimal port number in the UDP Port Number field to override
the default value.
3. Click Activate to save and activate the changes. The message Your
changes to the SNMP configuration have been successfully
activated appears.

Enable or Disable

the CLI Perform this procedure to toggle (enable or disable) the state of the
switch’s command line interface. To change the CLI state:
1. At the Configure panel, click the CLI tab. The Management page
displays with the CLI tab selected (Figure 2-97).
Figure 2-97 Configure Panel (Management Page with CLI Tab)
2. Perform one of the following steps as required: