B
Port Module Events (500 through 599) B-45
Event Code Tables

Port Module Events (500 through 599)

Event Code: 502
Message: Port module anomaly has been detected
Severity: Informational
Explanation: Indicates that the control processor has detected a deviation in the normal operating mode or operating status of
the indicated four-port hardware module.
Action: No action required. There will be an additional event code generated (504) if this occurrence exceeds an error
threshold, which results in a subsequent port module failure.
Event Data: Byte 0 = Slot position
Byte 1 = Anomaly reason code (See following chart).
0x00 = Common logic error
0x01 = ASIC common error
Bytes 4-7 = Elapsed millisecond tick count
Bytes 8-9 = High availability error callout #1
Bytes 10-11 = High availability error callout #2
Byte 12 = Detecting port
Byte 13 = Connected port
Byte 14 = Participating SBAR
Bytes 16-17 = High availability error callout #3
Bytes 18-19 = High availability error callout #4
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔