3
3-28 McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
Diagnostics

53

The link incident record provides the attached switch port number(s)
and one or more of the following event codes and messages. Record
all event codes that may relate to the reported problem.
581 - Link interface incident - implicit incident.
582 - Link interface incident - bit-error threshold exceeded.
583 - Link failure - loss of signal or loss of synchronization.
584 - Link failure - not-operational primitive sequence (NOS)
received.
585 - Link failure - primitive sequence timeout.
586 - Link failure - invalid primitive sequence received for the
current link state.
Were one or more event codes found?
YES NO
Perform switch fault isolation at the EFC Server.
Go to step 3.
Go to Table 3-3 on page 3-3.

MAP 0100: Power Distribution Analysis

This MAP describes fault isolation for the switch power distribution
system, including defective AC power cords or power supplies.
1
Was an event code 200, 201, 202, or 208 observed at the Sphereon
3032/3232 Event Log (EFC Server) or at the SANpilot event log?
YES NO
Go to step 3.
2
The following table lists event codes, brief explanations of the codes,
and the associated steps that describe fault isolation procedures.