14.3 Listing of Global Messages

Error

Message

Description

Canceling and Re-

Code

pairing Method

 

 

 

 

 

 

999

SHORT MON

This message is displayed, if MON (Ma-

This message causes

 

 

chine ON) output of control is short-cir-

EMG state and loss

 

 

cuited or overloaded.

of reference point. It

 

 

This message is generated in EMG state.

can be canceled by

 

 

 

RESET.

 

 

 

 

1020

POSITION ERROR

This message is displayed, if the position

The message is can-

 

 

lag does not reach the value specified at

celed by RESET

 

 

parameter within 5 seconds after the

key. In order to

 

 

interpolator has stopped. The above detec-

repair the cause of

 

 

tion is executed in case of command G00

error, the input

 

 

if parameter 1241 POSCHECK is 1, or in

offsets of the drives

 

 

case of feed movement in states G9 and

must be zeroed.

 

 

G61.

 

 

 

 

 

1100

REFERENCE POINT t1

This message is displayed, if the reference

The message is can-

 

 

point switch has not been found within the

celed by RESET

1110

 

 

distance specified at parameter REFDIS

key.

1120

 

(or if it cannot stop within that distance).

 

 

Value of t is the name of the axis: X, Y,

 

 

 

 

 

 

 

1130

 

Z, U, V, W, A, B, C.

 

 

 

In the error code (1100, 1110, 1120, ...)

 

1140

 

 

 

the digit on local value 10 (0, 1, 2, ...) +1

 

 

 

is the physical axis number.

 

1150

 

 

 

 

 

 

 

 

 

1160

 

 

 

 

 

 

 

1170

 

 

 

 

 

 

 

1101

REFERENCE POINT t2

This message is displayed if it cannot run

The message is can-

 

 

off the switch within the distance

celed by RESET

1111

 

 

specified at parameter SWLENGTH.

key.

1121

 

Value of t is the name of the axis: X, Y,

 

 

Z, U, V, W, A, B, C.

 

 

 

 

 

 

 

1131

 

In the error code (1101, 1111, 1121, ...)

 

 

 

the digit on local value 10 (0, 1, 2, ...) +1

 

1141

 

 

 

is the physical axis number.

 

 

 

 

 

1151

 

 

 

 

 

 

 

1171

 

 

 

125

Page 125
Image 125