NCT Group NCT 2000T, NCT 100T, NCT 990T manual 140

Models: NCT 100T NCT 990T NCT 2000T

1 144
Download 144 pages 29.53 Kb
Page 140
Image 140

14.3Listing of Global Messages

Error

 

Message

 

Description

Canceling and Re-

Code

 

 

pairing Method

 

 

 

 

 

 

 

3508

NC STATUS TABLE BAD

If the check sum of the memory area con-

The message is can-

 

 

 

 

taining the general NC state, preserved

celed by RESET

 

 

 

 

upon power-off is false.

key.

 

 

 

 

These data are as follows:

The listed data must

 

 

 

 

G20/G21: inch/metric input;

be reorganized.

 

 

 

 

the number of registered tool length

 

 

 

 

 

compensation (H), and the axis, on which

 

 

 

 

 

it is valid;

 

 

 

 

 

the programs selected for automatic or

 

 

 

 

 

MDI execution;

 

 

 

 

 

DNC state;

 

 

 

 

 

if the power is turned off during program

 

 

 

 

 

execution, the program number, the

 

 

 

 

 

execution of which, was interrupted.

 

 

 

 

 

3509

LIFE TIME TABLE BAD

If the check sum of the memory area con-

The message is can-

 

 

 

 

taining the life time table, preserved upon

celed by RESET

 

 

 

 

power-off is false.

key.

 

 

 

 

 

The life time table

 

 

 

 

 

must be reorganized.

 

 

 

 

 

 

3510

TOOL

OFFSET

TABLE

If the check sum of the memory area con-

The message is can-

 

BAD

 

 

taining the tool offset table, preserved

celed by RESET

 

 

 

 

upon power-off is false.

key.

 

 

 

 

 

The tool offset table

 

 

 

 

 

must be reorganized.

 

 

 

 

 

 

3511

WORK

OFFSET

TABLE

If the check sum of the memory area con-

The message is can-

 

BAD

 

 

taining the work zero point offset table,

celed by RESET

 

 

 

 

preserved upon power-off is false.

key.

 

 

 

 

 

The work zero point

 

 

 

 

 

offsets must be meas-

 

 

 

 

 

ured again.

 

 

 

 

 

3514

OVERRUN ERROR

 

This message is displayed if in DNC oper-

The message is can-

 

 

 

 

ation during serial transfer two bytes over-

celed by RESET

 

 

 

 

run without the previous one being read

key.

 

 

 

 

by the control.

Loading must be re-

 

 

 

 

 

started.

 

 

 

 

 

3515

PARITY ERROR

 

If in DNC operation through the serial

The message is can-

 

 

 

 

interface, the control receives data of

celed by RESET

 

 

 

 

incorrect parity . This message is also dis-

key.

 

 

 

 

played as a result of different parameter

Loading must be

 

 

 

 

settings on the transmitter and receiver

restarted.

 

 

 

 

side.

 

 

 

 

 

 

3516

FRAMING ERROR

 

It occurs in DNC operation. Framing error

The message is can-

 

 

 

 

is due to different parameter settings on

celed by RESET

 

 

 

 

the transmitter and receiver side.

key.

 

 

 

 

These are as follows:

Loading must be re-

 

 

 

 

baud rate,

started.

 

 

 

 

word length,

 

 

 

 

 

the number of stop bits.

 

140

Page 140
Image 140
NCT Group NCT 2000T, NCT 100T, NCT 990T manual 140