14.3Listing of Global Messages

Error

Message

Description

Canceling and Re-

Code

pairing Method

 

 

 

 

 

 

60

PLC TIMEOUT 1

If either module :001 or module :002 of

This message can

 

 

PLC program does not expire in the time

only be canceled by

 

 

slice reserved for it, message PLC TIME-

power-off of the con-

61

PLC TIMEOUT 2

OUT 1 or 2 is displayed.

trol. In order to

This message is generated in EMG state.

repair it, turn to a

 

 

 

 

 

well-trained expert.

 

 

 

 

70

DPG TIMEOUT

If the interpolation cycle does not expire

This message can

 

 

in the time slice reserved for it, message

only be canceled by

 

 

DPG TIMEOUT is displayed.

power-off of the con-

 

 

This message is generated in EMG state.

trol. In order to

 

 

 

repair it, turn to a

 

 

 

well-trained expert.

 

 

 

 

80

15V FAILURE

If the comparator circuit detects that the

This message can

 

 

specified voltage is not available at the

only be canceled by

 

 

+/–15V output of power supply, message

power off of the con-

 

 

15V Failure is displayed.

trol. In order to

 

 

This message is generated in EMG state.

repair it, turn to a

 

 

 

well-trained expert.

 

 

 

 

90

SYNC. FAILURE 1

If the movement of two axes is synchro-

This message causes

 

 

nized (gantry axes) and the position

EMG state and loss

91

SYNC. FAILURE 2

deviation value of the two axes is larger

of reference point. It

 

 

than the value set at parameter, message

can be canceled by

92

SYNC. FAILURE 3

SYNC. FAILURE n is displayed.

RESET.

93

SYNC. FAILURE 4

n=1...8 refers to the number of synchronic

 

axes.

 

 

 

 

94

SYNC. FAILURE 5

This message is generated in EMG state.

 

 

 

 

 

 

 

95

SYNC. FAILURE 6

 

 

 

 

 

 

96

SYNC. FAILURE 7

 

 

 

 

 

 

97

SYNC. FAILURE 8

 

 

 

 

 

 

100

SHORT 000

If an interface output line is short-

This message causes

 

 

circuited or overloaded, message SHORT

EMG state and loss

120

SHORT 020

ijk is displayed, where:

of reference point. It

200

SHORT 100

i=0 means the 1st, i=1 the 2nd, i=2 the

can be canceled by

3rd and i=3 the 4th interface card and j=0

RESET.

 

 

 

 

220

SHORT 120

means the first, while j=2 means the sec-

 

 

 

ond 16 output lines on the interface card.

 

300

SHORT 200

 

The short-circuited output line is not iden-

 

 

 

tified more exactly, k is always 0.

 

320

SHORT 220

 

This message is generated in EMG state.

 

 

 

 

400

SHORT 300

 

 

 

 

 

 

420