NCT Group NCT 2000T, NCT 100T, NCT 990T manual 131

Models: NCT 100T NCT 990T NCT 2000T

1 144
Download 144 pages 29.53 Kb
Page 131
Image 131

14.3 Listing of Global Messages

Error

Message

 

Description

Canceling and Re-

Code

 

pairing Method

 

 

 

 

 

 

 

 

3018

,A IN G2, G3

 

If in circular interpolation block (G2, G3)

The message is can-

 

 

 

angle (,A) has been programmed.

celed by RESET

 

 

 

 

key.

 

 

 

 

3019

D O M I N A T O R C O N -

If in 3D radius compensation calculation

The message is can-

 

STANT=0

 

the value of dominator constant is 0.

celed by RESET

 

 

 

 

key.

 

 

 

 

 

3020

DATA DEFINITION

ER-

If in block G33, G34

The message is can-

 

ROR G33,G34

 

more than 2 axes have been programmed,

celed by RESET

 

 

 

or

key.

 

 

 

both E and F are filled out, or

 

 

 

 

the thread lead is 0, or

 

 

 

 

,C or ,R has been programmed.

 

 

 

 

 

 

3021

G51 IN G33

 

If in block G33 scaling (G51) is on.

The message is can-

 

 

 

 

celed by RESET

 

 

 

 

key.

 

 

 

 

 

3022

DIVIDE BY 0 IN G33

 

If G33 has been programmed and

The message is can-

 

 

 

value E is less than or equal with 0, or

celed by RESET

 

 

 

the pulse number of spindle encoder on

key.

 

 

 

parameter 5023 ENCODERS1 is 0.

 

 

 

 

 

 

3023

DATA DEFINITION

ER-

In block G26 an address not interpreted

The message is can-

 

ROR G26

 

has been specified or there is a value

celed by RESET

 

 

 

specification error at an interpreted ad-

key.

 

 

 

dress.

 

 

 

 

 

3024

ERRONEOUS P VALUE IN

If in block G96 (programming constant

The message is can-

 

G96

 

surface speed) value P is not 1...9.

celed by RESET

 

 

 

 

key.

 

 

 

 

3025

DEFINITION ERROR S

If programmed spindle revolution (S) is

The message is can-

 

 

 

greater than 65000 or

celed by RESET

 

 

 

negative or

key.

 

 

 

in canned cycles G84.2, G84.3 equals to

 

 

 

 

0.

 

 

 

 

 

3026

DEFINITION ERROR G10

If in block G10 L3 (filling up the life time

The message is can-

 

L3

 

table) P or L are in one block under ad-

celed by RESET

 

 

 

dress T, H or D or other address was pro-

key.

 

 

 

grammed.

 

 

 

 

 

 

3027

DEFINIT. ERROR T

IN

If in block G10 L3 (filling up the life time

The message is can-

 

G10 L3

 

table) address T is defined without a

celed by RESET

 

 

 

group being referred to.

key.

 

 

 

 

3028

MORE TOOLS IN G10 L3

If in block G10 L3 (filling up life time ta-

The message is can-

 

 

 

ble) the number of tools within a group

celed by RESET

 

 

 

exceeds the maximum value registered on

key.

 

 

 

parameter 1181 GROUPNUM.

 

131

Page 131
Image 131
NCT Group NCT 2000T, NCT 100T, NCT 990T manual 131