3.6 SETTING Screens
3.6 SETTING Screens
The following screens can be found in this menu; LOCAL MACRO VARIABLES
3.6.1 Screen of LOCAL MACRO VARIABLES #1–#33
In the general displaying area the local macro variables and their values can be seen. In the five columns the main program and variables of the four possible macro levels are listed. A highlighting bar can be moved along the variables by means of
arrow keys
and
,
while with the help of arrows
and
the columns
can be switched over. Only those variables can be edited, of which the macro level
is already open. At first only level 0 can be edited, but in case a macro call occurred during program execution, this enables the editing of a further level. Till a macro level is not open, editing is unnecessary, for values are given to the variables suitable for the address chain in time of macro call, while the others are vacated.
Actions of LOCAL MACRO VARIABLES #1–#33 Screen
No action menu can be activated to this screen, by pressing action menu key a blank
action menu is displayed.
It is possible to give value directly to the macro variable by entering a number. If a vacant value is to be specified, #0 must be entered.
Values can be specified indirectly to the macro variables. This means, that in spite of giving a value, the variable containing the value must be entered. This way only variables
45