14.3 Listing of Global Messages

Error

Message

Description

Canceling and Re-

Code

pairing Method

 

 

 

 

 

 

2000

PLC ERROR 001

At most 152 different messages can be

The message is can-

 

 

sent by PLC. The message texts are

celed on the basis of

2001

PLC ERROR 002

optional. In case no text is added by the

the PLC program.

 

 

programmer of PLC, message PLC

 

2002

PLC ERROR 003

For information on

ERROR ijk is displayed.

 

 

...

 

 

clearing the mes-

 

 

sages turn to the ma-

 

 

For the list of messages and the descrip-

...

 

chine tool builder.

 

tion of messages turn to the machine tool

 

 

 

 

 

 

 

2150

PLC ERROR 151

builder.

 

 

 

 

 

2151

PLC ERROR 152

 

 

 

 

 

 

2500

PLC MESSAGE 1

At most 8 different indexed messages can

The message is clear-

 

 

be sent by PLC. The messages texts are

ed on the basis of

2501

PLC MESSAGE 2

optional. In case no text is added by the

the PLC program.

2502

PLC MESSAGE 3

programmer of PLC, text PLC MESSAGE

For information on

ijk is displayed.

 

 

 

 

2503

PLC MESSAGE 4

The message can be indexed with maxi-

clearing the mes-

 

 

mum 4 digits following the messages.

sages turn to the ma-

2504

PLC MESSAGE 5

For the list of messages and the descrip-

chine tool builder.

 

 

 

2505

PLC MESSAGE 6

 

tion of messages turn to the machine tool

 

 

 

 

2506

PLC MESSAGE 7

builder.

 

 

 

 

 

 

 

2507

PLC MESSAGE 8

 

 

 

 

 

 

3000

MIRROR IMAGE IN G51,

If mirror image (G50.1, G51.1) is

The message is can-

 

G68

switched on or off in the switched-on-state

celed by RESET

 

 

of scaling (G51), or rotation (G68).

key.

 

 

 

 

3001

VALUE EXCESS X,Y,...F

If coordinate or feed data exceeds value

The message is can-

 

 

range permitted.

celed by RESET

 

 

 

key.

 

 

 

 

3002

PLANE SELECTION IN

If plane selection (G17, G18, G19) is

The message is can-

 

G68

executed in the switched-on-state of

celed by RESET

 

 

coordinate rotation.

key.

 

 

 

 

3003

COORDINATE ADDRESS

If an axis outside the selected plane is

The message is can-

 

G68

specified in command G68 when giving

celed by RESET

 

 

the center of rotation.

key.

 

 

 

 

3004

MISSING REFERENCE

If reference point return has not been per-

The message is can-

 

POINT

formed before absolute movement is pro-

celed by RESET

 

 

grammed on an axis.

key.

 

 

 

 

3005

ILLEGAL G CODE

If no function or custom macro call has

The message is can-

 

 

been defined for a G code referred to or

celed by RESET

 

 

two or more conflicting G codes in a block

key.

 

 

are specified.

 

129