13 Interruption and Restart of Automatic Operation

13 Interruption and Restart of Automatic Operation

In many cases the automatic operation needs to be interrupted, than later on the machining to be continued. Cases like this for example when:

the errors must be repaired, than the machining continued when error messages are coming from program module preprocessor or PLC,

during machining the program may need to be corrected, for example because of syntactical error,

in case of tool break the broken tool must be retracted and replaced, than the machining continued with the a new tool and - if necessary - new offset values,

in some phases of machining the result needs to be examined, checked, than the machining continued,

if in course of the machining an obstacle, for example workpiece clamping is in the way of tool path it needs to be rounded, than the machining continued,

if work has to be paused, for example in case of power breakdown, than continued from the

interruption point.

The above cases require different types of intervention by the operator. The above problems must be repaired by means of services of the control discussed here.

13.1 Interruption of Automatic Operation

In the course of automatic operation the following interventions cause interrupted state:

appearance of emergency stop state, e.g. by pressing the EMERGENCY STOP button,

effect of the RESET key or

changing the operation mode

The interrupted state is indicated by caption INTD in the 3rd field of status bar. In interrupted state lots of manual interventions can be done on the control, which can be registered or canceled when restarting.

13.2Restart of the Automatic Operation. Modal Information. The automatic operation can be restarted in three ways in INTD state:

– unconditionally,

by means of the condition BLOCK RESTART or

by means of the condition BLOCK RETURN .

The difference among the three restart methods is that while in the first case if movement from interruption point has been made it goes to the block end position, in the second case it goes to the start position of the interrupted block and re-executes the whole block, and in the third case it moves back to interruption position and continues machining from there.

In the interrupted (INTD) state of automatic operation the modal information changes by entering a single block or running the program selected for manual data input mode. Therefore

101

Page 101
Image 101
NCT Group NCT 2000T, NCT 100T manual Interruption and Restart of Automatic Operation, Interruption of Automatic Operation