13.3 Unconditional Restart of Automatic Operation

When manual movement is done to a posi- tion, which is left from the end position of the circle, according to the diagram, the con- trol proceeds also as discussed above. How- ever this time the arc of the variable radius circle is close to 360° because of direction G03 according to the diagram.