10 Program Execution Start and Stop

10 Program Execution Start and Stop

The program execution is started by the use of the START button.

The program execution can be stopped by means of the following functions and keys:

with the STOP button,

with the RESET key,

at the end of block execution in the single block mode ,

after executing programmed stop command M00,

as the effect of conditional stop command M01, if optional stop switch is on,

after executing program end commands M02, M30.

10.1 Starting Program Execution

In the following cases the program execution is started by pressing START button :

in jog, incremental jog or manual handle feed mode, after single block has been entered and terminated,

in automatic mode, if program is selected for execution from memory or DNC,

in manual data input mode, if program is selected for execution.

Error message

NOT EXISTING PROGRAM

is displayed by pressing START button, if no program is selected for execution. START state is indicated by caption STRT in the 3rd field of status bar.

10.2 Feed Stop

During program execution by pressing STOP button START state is cancelled. The

axes decelerate and stop. The execution of functions (M, S, T, B) in the given block is continued till the end of block. STOP state is indicated by caption STOP in the 3rd field of the status bar.

In the following cases the STOP button is ineffective:

G63, i.e. state of override inhibit,

values of variable #3004 listed in programmer’s manual, and

during thread cutting G33, G34 and tapping cycles G84.1, G84.

10.3 RESET

If reset key is pressed during program execution, START or STOP state is canceled.

The axes decelerate and stop, even if control executes operation, where the use of feedrate override switches and STOP button is ineffective (e.g.: G33, G34, G76, G78, G84.1, G84).

92