14.3 Listing of Global Messages

 

 

 

 

 

 

Error

Message

Description

Canceling and Re-

Code

pairing Method

 

 

 

 

 

 

 

 

 

 

3123

 

 

 

 

 

 

 

 

 

 

 

3124

 

 

 

 

 

 

 

 

 

 

 

3125

 

 

 

 

 

 

 

 

 

 

 

3126

 

 

 

 

 

 

 

 

 

 

 

3127

 

 

 

 

 

 

 

 

 

3500

PROGRAM EDITED

This message is displayed, if program se-

The message is can-

 

 

lected for automatic execution is edited in

celed by RESET

 

 

automatic mode, or

key.

 

 

if program selected for manual data input

The program can be

 

 

execution is edited in MDI mode,

started if the EDIT

 

 

meanwhile START is pressed.

screen is closed after

 

 

 

 

 

terminating editing.

 

 

 

 

3502

BAD BAUD RATE VALUE

If not standard baud rate value or a baud

The message is can-

 

 

rate that cannot be interpreted by control

celed by RESET

 

 

is set at parameter 2002 BAUD RATE. It

key.

 

 

is displayed in DNC mode. The values

 

 

 

interpreted by the control are listed in the

 

 

 

description of parameters.

 

 

 

 

 

3503

SERIAL BUFFER FULL

If the serial buffer has been overrun in the

The message is can-

 

 

course of DNC machining.

celed by RESET

 

 

 

 

 

key.

 

 

 

 

 

Data transfer must be

 

 

 

 

 

restarted.

 

 

 

 

3504

TOOL PLACE TABLE BAD

If NC finds the check sum of the tool pot

The message is can-

 

 

table false.

celed by RESET

 

 

 

 

 

key.

 

 

 

 

 

Tool pot table must

 

 

 

 

 

be reorganized.

 

 

 

 

3505

N O T E X I S T I N G

If a program had been selected for auto-

The message is can-

 

PROGRAM

matic or MDI execution, than the program

celed by RESET

 

 

was deleted and without selecting a new

key.

 

 

program START is pressed in automatic

 

 

 

or MDI mode.

 

 

 

 

 

3507

OVERWRITE (Y/N)

If the program being executed loads pro-

If the old program is

 

 

gram to the control memory by means of

to be overwritten key

 

 

command DPRNT, with the number of

Y must be pressed,

 

 

which a program has already been regis-

otherwise key N or

 

 

tered in the directory.

RESET.