14.3 Listing of Global Messages

Error

Message

Description

Canceling and Re-

Code

pairing Method

 

 

 

 

 

 

 

3086

DEFINITION ERROR G51

If scaling axis by axis is programmed

The message is can-

 

 

 

(G51 X Y Z I J K) and X and U, or Y and

celed by RESET

 

 

 

V, or Z and W are in one block.

key.

 

 

 

 

3087

ILLEGAL PLANE SELECT

If in G76 multiple thread cutting cycle, on

The message is can-

 

 

 

lathe control, not G18 plane is selected.

celed by RESET

 

 

 

 

key.

 

 

 

 

 

3088

FORBIDDEN

SPINDLE

If no spindle encoder is on the machine

The message is can-

 

MOVING

 

and an instruction demanding spindle en-

celed by RESET

 

 

 

coder has been programmed (e.g. thread

key.

 

 

 

cutting, orientation).

 

 

 

 

 

3089

BUFFER OVERRUN G41,

If buffer has been overrun in offset mode

The message is can-

 

G42

 

(G41, G42).

celed by RESET

 

 

 

 

key.

 

 

 

 

 

3090

# DEFINITION

PROHIB-

Defining prohibited macro variable (#....).

The message is can-

 

ITED

 

This may be due to its type (e.g., #1000,

celed by RESET

 

 

 

... #1015), or it may be prohibited at

key.

 

 

 

parameters 9101 WRPROT1, 9102

 

 

 

 

WRPROT2.

 

 

 

 

 

3091

ERRONEOUS OPERATION

If, in case of macro variables (#...), the

The message is can-

 

WITH #

 

operands and operations conflict. E.g.: if

celed by RESET

 

 

 

logical addition (AND) has been com-

key.

 

 

 

manded between macro variables that can-

 

 

 

 

not be represented in 32 bits in fix point

 

 

 

 

mode.

 

 

 

 

 

3092

DIVISION BY 0 #

If, in case of evaluating a macro

The message is can-

 

 

 

expression, division is to be done by 0.

celed by RESET

 

 

 

 

key.

 

 

 

 

3093

BUFFER OVERRUN #

Buffer has been overrun with macro vari-

The message is can-

 

 

 

ables.

celed by RESET

 

 

 

 

key.

 

 

 

 

 

3094

 

 

 

 

 

 

 

 

 

3095

 

 

 

 

 

 

 

 

 

3096

 

 

 

 

 

 

 

 

 

3097

 

 

 

 

 

 

 

 

3098

ERRONEOUS ARGUMENT

If the function value exceeds the range.

The message is can-

 

 

 

If e.g., SQRT[-4] or ASIN[2]),

celed by RESET

 

 

 

if, in case of instruction BCD, the

key.

 

 

 

transformed number is of more than 8

 

 

 

 

digits,

 

 

 

 

if, in case of instruction BIN, not a BCD

 

 

 

 

number is defined on the decades.

 

 

 

 

 

 