Technical Specifications B

The technical specifications for the Models 3160/3164 DSU/CSUs are listed in Table B-1. The technical specifications for the Model 3161 DSU/CSU are listed in Table B-2.

Table B-1

(1 of 2)

ACCULINK Models 3160/3164 DSU/CSUs Technical Specifications

Specifications

Criteria

 

 

POWER REQUIREMENTS

 

Typical

104±132 Vac; 60 Hz ±3; 0.15A at 115 Vac for 3160, 0.175A at 115 Vac for 3164

Options:

 

+24 Vdc

+20 Vdc to +32 Vdc, 0.50A

±48 Vdc

±38 Vdc to ±60 Vdc, 0.25A

±48 Vdc Redundant

±38 Vdc to ±60 Vdc, 0.25A

 

 

POWER CONSUMPTION AND

16.0 watts, 55.0 Btu per hour at 115 volts(ac power); 12.0 watts, 41 Btu per hour

DISSIPATION

at +24 and ±48 Vdc (dc power)

 

 

DTE (DSX-1) INTERFACE

 

Physical Interface

DB15 socket

Framing Format

D4, ESF

Coding Format

AMI, B8ZS

DTE Line Equalization

5 selectable ranges from 0 to 655 feet (0 to 196.5 meters)

Send AIS

Selectable

 

 

NETWORK T1 INTERFACE

 

Physical Interface (USA)

RJ48C

Physical Interface (Canada)

CA81A using adapter cable

Framing Format

D4, ESF

Coding Format

AMI, B8ZS

Line Build-Out (LBO)

0.0 dB, ±7.5 dB, ±15 dB, ±22.5 dB

ANSI PRM

Selectable

Bit Stuffing

FCC Part 68, AT&T TR 62411

Yellow Alarm Generation

Selectable

 

 

LOOPBACKS

 

Standard

AT&T TR 54016, AT&T TR 62411, ANSI T1.403.1989

Additional

RLB (Repeater Loopback), DLB (DTE Loopback), V.54 Loop 2 and Loop 3,

 

ANSI T1.403 Annex B Fractional T1 Loopback

 

 

PORT INTERFACE

Standards

Rates

EIA 530A, V.35, RS±449, V.11

Nx64 ± 64-1.536 Mb

Nx56 ± 56-1.344 Mb

3160-A2-GB22-10

December 1996

B-1

Page 138
Image 138
Paradyne 316x manual Technical Specifications B, Power Requirements