Test Jack Functions

ACCULINK 316x DSU/CSU

 

Table 3-6

 

Test Jack Functions

 

 

Test Jack Name

Function

 

 

Net In

A break-in and test jack that allows a signal to be inserted toward the network by

(Network In)

external test equipment. The signal is inserted on the DSX-1 side of the

 

DSU/CSU.

 

 

Net Out

A break-in and test jack that interrupts the signal coming from the network and

(Network Out)

allows it to be terminated by the external test equipment.

 

 

Net Mon In

A monitor jack that nonintrusively monitors the incoming signal from the network.

(Monitor Network)

 

 

 

Net Mon Out

A monitor jack that nonintrusively monitors the incoming signal from the DSX-1.

(Monitor DSX-1)

 

 

 

Eqp Mon Net

A break-in and test jack that allows a signal to be inserted toward the DSX-1 by

(Equipment In)

external test equipment.

 

 

Eqp Mon Eq

A break-in and test jack that interrupts the signal coming from the DSX-1 and

(Equipment Out)

allows it to be terminated by the external test equipment.

 

 

Configuring the DSU/CSU

You have the option of customizing your 316x DSU/CSU for optimum performance in your network. To do so, use the DSU/CSU configuration options. Appendix G contains a set of blank worksheets to use when configuring your 316x DSU/CSU in the network.

Configuration Option Areas

The 316x DSU/CSU offers four sets of configuration options located in the following areas:

Active (Activ). The configuration option set active for the DSU/CSU is stored here. Before a set of configuration options become active for the DSU/CSU, you must save the set to the Active area. When the DSU/CSU is shipped from the factory, the Active configuration option set is identical to both the Customer and the Factory 1 sets. This area can be written to and controls the current operation of the device.

Customer (Cust). This is the set of customer-defined configuration options. Customer set is identical to the Factory 1 set when the DSU/CSU is shipped from the factory. This area can be written to.

Factory 1 (Fact1). This is a set of configuration options preset at the company. This set is determined by what is considered to be the most common configuration used in the DSU/CSU market. Factory 1 options are read-only.

Factory 2 (Fact2). This is a set of configuration options preset at the company. This set is determined by what is considered to be the second most common configuration used in the DSU/CSU market. Factory 2 options are read-only.

Configuration Options

The configuration options are divided into seven functional groups. Appendix C contains a list of the configuration options and defaults. These groups are:

DTE (DSX-1) Interface (see Table C-1)

Port (see Table C-2)

Network Interface (see Table C-3)

Channel (see Tables C-4 and C-5)

General (see Table C-6)

User Interface (see Table C-7)

Alarm (see Table C-8)

General SNMP (see Table C-9)

SNMP Trap (see Table C-10)

3-16

December 1996

3160-A2-GB22-10