Paradyne 316x manual Configuring for Network Timing Example

Models: 316x

1 211
Download 211 pages 11.69 Kb
Page 92
Image 92
Configuring for Network Timing Example

ACCULINK 316x DSU/CSU

Configuring for Network Timing Example

To configure network timing,

1.Press F3 to select Cnfig from the top-level menu screen.

DSU ESF

Stat Test Cnfig

F1 F2 F3

2.Select the configuration option set to be copied into the Edit area by using the appropriate function key. Use the scroll keys, if necessary.

Load from:

 

Activ

Cust

Fact1

F1

F2

F3

3. Press F1 to select Edit.

Choose Funct:

Edit Save

F1 F2 F3

4.From the Edit screen, press the Manual background key twice to bring the Gen selection onto the screen.

Edit:

DTE Port NET

F1 F2 F3

5.Press F3 to select Gen for the general configuration options.

Edit:

NET Chan Gen

F1 F2 F3

6.The Generate Yellow Alarm configuration option displays first. Press F1 (Next) once to display the DSU/CSU Clock Source configuration option.

GenYellow:Enab

Next Enab Disab

F1 F2 F3

7.Select the master clock source. For network, press F2 (note that network is also the default).

Clock Src:NET

Next NET DTE

F1 F2 F3

Differences Using the Async Terminal: To configure network timing, select General from the main/configuration/edit menu.

3-50

December 1996

3160-A2-GB22-10

Page 92