Displaying LED Conditions on the Front Panel

The same conditions monitored by the front panel LEDs can also be monitored by the LED command. This command is most useful when the DSU/CSU is being accessed remotely.

NOTE

No LEDs are shown on the PC's front panel emulation screen. You must use the Stat command procedure described below to get LED information.

To display LED conditions on the front panel screen,

1.Press F1 to select Stat from the top-level menu screen.

DSU ESF

Stat Test Cnfig

F1 F2 F3

2.From the Status screen, press the key twice to display the LED selection.

Status:

 

 

DevHS STest

Perf

F1

F2

F3

3. Press F3 to select LED from the Status screen.

Status:

Perf TStat LED

F1 F2 F3

4.From the Select LEDs screen, press the function key that corresponds to the T1 or port for which you want to display LEDs. Use the scroll keys, if necessary.

Select LEDs:

T1 Prt1 Prt2

F1 F2 F3

If you chose T1, the LED Display screen lists the LED signals, two at a time, on the second line. A vertical bar at the left of the LED name indicates the condition is ON, while no bar indicates the condition is Off.

LED Display:

Test NetSig

F1 F2 F3

If you chose a port, the Port n LEDs screen lists the LED signals, two at a time, on the second line. A vertical bar at the left of the LED name indicates the condition is ON, while no bar indicates the condition is Off.

Port n LEDs:

DTR TXD

F1 F2 F3

5.Use the and keys to scroll LED names onto the screen.

Differences Using Async Terminal: You can monitor LED status using the Display LEDs selection under the main/status menu.

Figure 3-7 shows an example of the LED Status screen on the async terminal when all four ports are configured. Unlike the front panel display, you can view all the LED conditions at one time for the ports, the network, and T1 interface. There are no shared LEDs so you do not need to select which port status should appear on this screen.

3160-A2-GB22-10

December 1996

3-11